The inspection station is only as good as its cable
A vision station is commissioned against a set of golden parts, it passes, and six weeks later the false-reject rate climbs. The camera has not moved, the lens has not been touched and the lighting measures the same on the meter. What has changed is usually the cable: it has been flexed a few hundred thousand times, its shield has been working against the inside of a carrier, or the link has started retraining every time the spindle comes up to speed.
Cables are the least specified part of a vision station because they sit between two things that engineers do specify carefully, which are the camera and the host. Yet the cable sets the two numbers that actually decide whether the station works: how much data can cross the link per second, and how reliably it crosses while the machine is running. It also decides where the host computer can physically sit, which in a cell is often the difference between a PC in a clean cabinet and a PC strapped to a gantry.
The choice normally comes down to GigE Vision or USB3 Vision, and the comparison is not "which is faster". It is distance, power delivery, determinism, and what the cable has to survive mechanically at the station. Those four are usually decided by the machine layout, not by the camera datasheet.
Bandwidth first: from resolution and frame rate back to the link
Start with the arithmetic, because it settles most of the argument before the mechanical questions come up. The payload is pixels × bytes per pixel × frames per second. A mono 8-bit image is one byte per pixel; a Bayer raw transfer is also one byte per pixel; an RGB transfer is three.
A 5 MP sensor at 2448 × 2048, mono 8-bit, running at 20 fps is about 100 MB/s. A 2 MP sensor at 1920 × 1200 running at 60 fps is about 138 MB/s. A 12 MP sensor at 4096 × 3072 running at 10 fps is about 126 MB/s. Move to colour and the same sensors triple, which is why many colour stations transfer Bayer and demosaic on the host.
Against those numbers, the sustained payload of each link is roughly 110 to 115 MB/s for GigE Vision and 350 to 400 MB/s for USB3 Vision, with 10GigE sitting near 1.1 GB/s. Leave 20 to 25 per cent of headroom, because the frame overhead, the resend traffic and the host's own interrupt load all come out of the same budget.
| Sensor and rate (mono 8-bit) | Payload | GigE Vision | USB3 Vision | 10GigE |
|---|---|---|---|---|
| 1.3 MP at 30 fps | ~39 MB/s | Comfortable | Comfortable | Comfortable |
| 5 MP at 20 fps | ~100 MB/s | Near the limit | Comfortable | Comfortable |
| 2 MP at 60 fps | ~138 MB/s | Over budget | Comfortable | Comfortable |
| 5 MP at 45 fps | ~225 MB/s | Over budget | Comfortable | Comfortable |
| 12 MP at 10 fps | ~126 MB/s | Over budget | Comfortable | Comfortable |
| 12 MP at 30 fps | ~377 MB/s | Over budget | Near the limit | Comfortable |
| 5 MP colour RGB at 20 fps | ~300 MB/s | Over budget | Comfortable | Comfortable |
One note on overhead before reading the table too literally. GigE Vision packetises each frame, and the inter-packet gap, the header and the resend buffer all come out of the same 110 MB/s. Budgeting a camera to the full link rate is the most common way to build a station that works in the demo and resends in production.
The pattern in the table is why USB3 dominates high-resolution stations: anything above roughly 110 MB/s is off the table for a single GigE link. It is also why GigE is still everywhere in multi-camera cells, where each camera needs far less than that and the value is in the cabling rather than in the bandwidth.
GigE Vision on the station: distance, PoE and jitter
The first advantage is distance. A copper Ethernet segment is 100 m, and it runs over ordinary structured cabling with RJ45 or M12 X-coded connectors, cheap switches and standard test equipment. In a machine cell 100 m is far more than anyone needs, but the practical benefit is that the host PC can sit in a cabinet away from the coolant while the camera sits at the station.
The second is power. Power over Ethernet carries data and supply on the same four pairs: 802.3af delivers about 13 W at the camera, 802.3at about 25 W, and 802.3bt Type 3 about 51 W. Most 5 MP cameras draw between 3 and 8 W, so af is usually enough; cameras with on-board preprocessing or integrated lighting need at or bt. The drop over 100 m is manageable because the standard allows roughly 13 V of it, and 24 AWG structured cable at typical camera current drops only a few volts.
The third consideration is the one that catches people out, and it is timing. GigE Vision is packetised, so latency sits in the millisecond range and, more importantly, it jitters. A few hundred microseconds of variation is normal, and it is driven by packet size, driver behaviour and interrupt moderation on the host. Where capture is triggered from an encoder and the result has to be positionally repeatable, that jitter is the specification to check rather than the bandwidth.
One more: a copper GigE run connects the grounds of two chassis through the cable shield. Within one machine that is helpful. Across a cell where the camera is on a frame at one potential and the host cabinet sits at another, it is a ground loop waiting for a fault to make itself visible.
Sourcing is straightforward here, and a mainstream industrial communication cable range will cover the Cat5e through Cat6a assemblies most stations need, with the shielding and jacket options that matter once the cable leaves the cabinet.
USB3 Vision on the station: bandwidth, distance and power
Bandwidth is the reason to choose it. At 350 to 400 MB/s sustained, one USB3 Vision link carries what three GigE links would, which is why nearly every high-resolution or high-frame-rate sensor in the catalogues is a USB3 part.
Distance is the constraint that comes with it. Passive copper USB 3.x is realistically about 3 m for a full-rate link, with 5 m achievable on a well-built assembly, and active or optical cables extending that to 10 m and beyond. If the host PC sits in a cabinet more than about 5 m from the station, USB3 is the wrong physical layer, and the honest answer is 10GigE rather than an increasingly exotic USB3 cable.
Power is the second constraint and it is tighter than people expect. USB3 Vision bus power is 5 V at 900 mA, which is 4.5 W, and the tolerance is 5 per cent, so the total drop budget is about 0.25 V. Over a 2 m cable that is 4 m of conductor: 24 AWG at 0.9 A drops roughly 0.30 V and fails, while 20 AWG drops about 0.12 V and passes. That is why USB3 Vision assemblies quote the power conductor gauge separately from the SuperSpeed pair gauge, and why any camera drawing real power should be supplied externally.
One genuine advantage: the USB3 Vision standard mandates a latching connector, typically two M2 screws. On a station bolted to a machine that vibrates, having the retention built into the standard rather than offered as an option removes an entire class of intermittent fault.
Drag-chain flex life, shielding and grounding
If the camera is on a moving axis, the cable is a continuous-flex component and everything else is secondary. Look for a rated cycle count at a named bend radius, tested in a carrier at a named speed and stroke. Five to ten million cycles is the usual claim, and it means nothing without those three qualifiers attached to it. The corollary is that a cable rated for static use, however good it is, is the wrong part on a moving axis, and the failure will not present as a cable failure. It will present as the camera occasionally missing a frame.
For GigE that means an S/FTP construction with stranded rather than solid conductors, a PUR or equivalent oil-resistant jacket, and a bend radius in motion of roughly ten times the overall diameter. For USB3 the same discipline applies, with the added condition that the connector is the locking type the standard calls for.
Shielding is not optional in either case, because the vision cable runs in the same tray as servo power. Braid plus foil, a 360-degree termination at the connector, and a shell that bonds to the camera body and to the host. A plug with an unbonded overmould leaves the shield ending a few centimetres short of where it is needed, which is the classic cause of dropouts that only occur when the spindle is cutting.
Grounding deserves a decision rather than a default. Bond the camera chassis to the machine frame with a short strap, and be deliberate about where the cable shield lands at each end. Where the run crosses between cabinets at different potentials, either use an isolated camera or move to fibre, because a copper shield between two grounds is not a shield, it is a conductor.
These are the requirements we hand to suppliers when a station goes on a moving axis, and the reason we buy from ranges of industrial cable assemblies built for continuous flex rather than adapting an office-grade patch lead. The failure mode for the adapted cable is not immediate; it is a slow climb in resends over about six weeks.

Choosing per station
Put the four decision criteria side by side and the choice usually makes itself.
| Criterion | GigE Vision | USB3 Vision |
|---|---|---|
| Sustained payload | 110-115 MB/s | 350-400 MB/s |
| Copper distance | 100 m per segment | 3-5 m passive, longer with active or optical |
| Power over the link | PoE, 13 W to 51 W at the camera | 4.5 W bus power |
| Latency and jitter | Milliseconds, jitter in the hundreds of microseconds | Sub-millisecond and more repeatable |
| Connector | RJ45 or M12 X-coded, latch often optional | Locking USB-C or micro-B, two M2 screws mandatory |
| Infrastructure | Standard structured cabling, cheap switches | Dedicated assemblies, active cables are expensive |
| Best fit | Multi-camera cells, long runs, host in a remote cabinet | One high-resolution station with the host nearby |
The rule we work to is short. If the host is within about 3 m of the station and the sensor needs more than 110 MB/s, USB3 Vision. If the run is long, or several cameras share one host across a cell, GigE Vision. If you need both bandwidth and distance, stop comparing the two and go to 10GigE, where the trade is a more expensive NIC and a cable that has to be treated with more respect.
Acceptance testing the installed link
Run the camera at its full rate with the production trigger scheme for an hour and read the dropped-frame and resend counters at the host. Any resend traffic at commissioning will be worse in production, when the machine is warm and the drives are loaded, so the target is zero rather than "small". A station that starts production with resends already in the log is a station whose false-reject rate will drift.
Then exercise the mechanics. Run the axis through its full stroke for the number of cycles a production day represents, monitoring frame delivery throughout. A cable failing in a carrier degrades gradually, so the signature is a counter that climbs over the test rather than a link that falls over.
Then add the noise. Run the spindle, then the coolant pump, then the variable-frequency drive at several speeds, and watch the same counters. Dropouts that appear at one particular drive speed are coupling, and no amount of extra bandwidth will fix them; the shield termination will.
Finally, record the cable part number, the exact length, the carrier model and the install date on the station build sheet, and keep one spare built to the same length. On a station running three shifts, the cable is the component that wears out first, and it is the one nobody has a part number for. A supplier that builds to a specified length, such as the industrial cable assembly partner we use for station wiring, will usually stamp or label the assembly so it can be reordered without a drawing.
Frequently asked
Can I run USB3 Vision over 10 metres?
Only with an active repeater or optical assembly. Passive copper USB 3.x is realistically 3 m for a full-rate link and 5 m on a good assembly, and buying a longer passive cable usually produces a link that trains and then resends.
Does PoE really work over a full 100 m?
Yes for typical cameras. 802.3af delivers about 13 W at the camera, most 5 MP units draw 3 to 8 W, and the standard allows roughly 13 V of drop, which 24 AWG structured cable stays comfortably inside over 100 m.
How do I know whether a vision cable is failing?
Watch the dropped-frame and resend counters at the host and correlate them with axis position or spindle speed. A cable failing in a carrier degrades gradually, so the counters climb over days rather than failing outright.
Does a two-metre vision cable need shielding?
Yes, if it runs anywhere near servo power. Length is not what decides it. A short cable sharing a tray with a drive output couples just as effectively as a long one, and the shield is the only thing in the way.